| MODEL |
GR2 550VA |
GR2 650VA |
GR2 1000VA |
Glamor 1200 |
Glamor 1600 |
Glamor 2000 |
| INPUT |
Voltage Range(VAC) |
160 ~ 290VAC |
| Frequency Range(Hz) |
50 / 60Hz (auto sensing) |
| OUTPUT |
Capacity(VA/W) |
550 / 250 |
650 / 360 |
1000 / 500 |
1200 / 600 |
1600 / 900 |
2000 / 1200 |
| Voltage(VAC) |
220 / 230 / 240VAC (default 230VAC) |
| Voltage Range(VAC) @ Battery Mode |
220 / 230 / 240VAC ±10% (Before Battery Low) |
| Frequency Range(Hz) @ Battery Mode |
50 / 60Hz ± 1Hz |
| Transfer Time |
2 ~ 6ms (typical), 10ms (max.) |
| Waveform @ Battery Mode |
Simulated Sinewave |
| BATTERY |
Battery Type |
VRLA, sealed lead acid maintenance free |
| Capacity and Number |
12V / 5Ah x 1 |
12V / 7Ah x 1 |
12V / 7Ah x 1 or 12V / 9Ah x 1 |
12V / 7Ah x 2 |
12V / 7Ah x 2 |
12V / 9Ah x 2 |
| Voltage(Vdc) |
12 |
12 |
12 |
24 |
24 |
24 |
| Typical Charger Time |
4 ~ 6 hours recover to 90% capacity |
| INDICATOR |
LED |
3 LEDs: Line mode, Battery mode and Fault |
6 LEDs: Line mode, Battery mode, Fault, Load % and Batt. Capacity |
| LCD (Option) |
Line mode, AVR mode, Battery mode, Battery capacity, Load level, Input voltage, Output voltage, Fault and Battery weak |
| ALARM |
Audible or Visual |
Battery mode, Low battery, Overload and Fault |
| OUTLET |
Backup |
(4) IEC 320-C13 |
(6) IEC 320-C13 |
| PROTECTION |
Full Protection |
Overload, Discharge, Overcharge, ABDM, Short circuit and RJ-11 / RJ-45 surge protection (Option) |
| FUNCTION |
DC Start |
Yes |
| AC Auto Restart |
Yes |
| Plug-in Charging |
Yes |
| ABDM |
Yes |
| A.V.R |
Boost x 1 and Buck x 1 |
| PHYSICAL |
Dimensions (WxHxD in mm/inch) |
100 X 140 X 292.2 / 3.9 × 5.5 × 11.5 |
148 x 198 x 315 / 5.8 x 7.8 x 12.4 |
| Net Weight (kgs/lbs) |
3.6 / 7.9 |
4.5 / 9.9 |
5.0 / 11.0 |
9.0 / 19.8 |
10.5 / 23.1 |
11.8 / 26.0 |
| Shipping Weight (kgs/lbs) |
3.9 / 8.5 |
4.8 / 10.5 |
5.3 / 11.6 |
10.0 / 22.0 |
11.5 / 25.4 |
12.8 / 28.2 |
| ENVIRONMENT |
Operation Temperature |
0 ~ 40°C / 32 ~ 104℉ |
| Storage Temperature |
-10 to +40℃(+14 to +104°F) |
| Operation Humidity |
0 ~ 90%RH, non-condensing |
| Altitude |
1000meters without derating |
| Noise Level |
< 40dBA @ 1 meter front |
< 45dBA @ 1 meter front |
| COMMUNICATION |
Interface (Option) |
USB, RS232, RJ45(UL), USB Charger(5V/1A,1A1C) |
USB, RS-232 |
| Compatible Platforms |
Microsoft Windows series, Linux, Mac, etc. |
STANDARDS & CERTIFICATIONS** |
Safety |
IEC EN 62040-1 |
| EMC |
EN IEC 62040-2:2018 C2 |
IEC EN 62040-2, EN61000-3-2, EN61000-3-3 |
| Marks |
CE |
|
| * Specifications subject to change without notice, and the final explanation rights are reserved by Ablerex. |
| ** Depending on the model and rating voltage, please contact Ablerex for more information. |
| *** The same technical specification may be sold in diferent countries under different model names, please consult Ablerex for more information. |
|